EcoFlow DELTA 2 Max
- Capacity
- 2,048 Wh
- AC Output
- 2,400 W
- Peak Surge
- 4,800 W
- Max Solar
- 1,000 W
Serious 2kWh outage unit with dual MPPT 1,000W solar input and 4,800W peak surge handling.
Verified runtime calculation, startup surge check, and solar recharge math for pairing the 2,048Wh EcoFlow DELTA 2 Max with a 75W cpap (heated).
Pre-loaded with manufacturer specs for EcoFlow DELTA 2 Max and typical cpap (heated) draw. Adjust your exact wattage label below.
At 75W running draw and 90W startup surge, the EcoFlow DELTA 2 Max retains 96.9% continuous AC headroom and 98.1% surge headroom. Accounting for a realistic 100% duty cycle and 15W AC inverter idle consumption, average draw is 90.0W against 1,741Wh of usable battery energy (85% AC conversion efficiency). Without AC inverter overhead, theoretical runtime would reach 23.2 hours.
For a 24-hour blackout, running this cpap (heated) alone uses roughly 720Wh of battery energy. A single EcoFlow DELTA 2 Max (1,741Wh usable) covers a full day without recharging.
Assumes 4.5 US average peak sun hours/day and 75% real-world solar derating (heat, angle, MPPT loss).
| Solar Array | Real Charging Power | 0–90% Charge Time | Daily Harvest | Daily Balance vs Load |
|---|---|---|---|---|
| 200W Solar Array | 150 W | 12.3 hrs | 675 Wh/day | -45 Wh deficit |
| 400W Solar Array | 300 W | 6.1 hrs | 1,350 Wh/day | Self-sustaining (+630 Wh) |
| 800W Solar Array | 600 W | 3.1 hrs | 2,700 Wh/day | Self-sustaining (+1,980 Wh) |
| Power Station | Capacity | AC / Surge Limit | Surge Check | Est. Runtime |
|---|---|---|---|---|
| EcoFlow DELTA 2 Max (Selected) | 2,048 Wh | 2,400 W / 4,800 W | PASS | 19.3 hrs |
| EcoFlow DELTA Pro | 3,600 Wh | 3,600 W / 7,200 W | PASS | 34.0 hrs |
| Bluetti AC200L | 2,048 Wh | 2,400 W / 3,600 W | PASS | 19.3 hrs |
| Anker SOLIX F2000 | 2,048 Wh | 2,400 W / 3,600 W | PASS | 19.3 hrs |
Specs verified from manufacturer datasheets. Affiliate links keep GridSizing free (disclosure).
Serious 2kWh outage unit with dual MPPT 1,000W solar input and 4,800W peak surge handling.
Multi-day whole-circuit backup with 3,600Wh base capacity, 7,200W surge, and 1,600W solar (240V available with dual-unit hub).
Multi-day outage & RV backup with 1,200W solar recharging and large battery expansion.
Expect about 19.3 hours (0.81 days) using 75W running draw, 100% compressor/usage duty cycle, 85% AC inverter efficiency, and 15W idle overhead.
Yes. The EcoFlow DELTA 2 Max supports up to 4,800W peak surge compared with the typical 90W startup spike of a CPAP (Heated), leaving 98.1% surge margin.
The EcoFlow DELTA 2 Max accepts up to 1,000W of solar input. With a 400W solar array in 4.5 peak sun hours (75% real-world derate), you harvest roughly 1,350Wh per sunny day.
Compare all 11 LiFePO4 backup stations → · Size a full multi-appliance home outage →